First you
survey
property for existing underground obstacles, such as
water, gas, electrical or sprinkler systems.
-
Then you dig
an entry access point.
-
After that dig
an exit access point
-
 
Fuse new pipe together for the length of the pull and
attach bullet cutting head.
-
String
pull line through existing old pipe.
-
Attach
pull line to new pipe and bullet burster.
-
Setup
hydraulic pulling mechanism at the exist side of job
-
Start
pulling new pipe through old pipe. Burtsting the old
pipe as it is being pulled along.
-
Once
complete, cut off bursting head and attach pipes to
the house on one end and the exit point on the other
end. Installing all necessary cleanouts.
-
Fill
in entry and exit access points and compact.
The job is now complete, with
very little destruction to landscaping and minimal downtime
of your plumbing system. All necessary permits are obtained
and all city and county inspections are done to insure
proper installation. |
|